當(dāng)前位置:首頁產(chǎn)品中心離心機(jī)臺式大容量離心機(jī)SG-852-type large-capacity centrifuge
large-capacity centrifuge

產(chǎn)品簡介

SG-852-type large-capacity centrifuge is the company according to the user experience,Carefully design and development of a new generation of centrifuges products

產(chǎn)品型號:SG-852-type
更新時(shí)間:2019-05-05
廠商性質(zhì):生產(chǎn)廠家
訪問量:3621
詳細(xì)介紹在線留言

Product Introduction:
SG-852-type large-capacity centrifuge is  the company  according to the user experience,Carefully design and development of a new generation of centrifuges products, and compared to similar products with higher quality advantage:apply to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use. is applicable to all types of laboratory samples of high-capacity centrifugal precision laboratory instruments.
Product features:
1, outstanding performance: micro-computer control, frequency control DC, brushless DC motor without carbon powder pollution;
2, simple: touch panel, digital display, intuitive and reliable;
3, high-capacity multi-rotor, the user easily select
Technical data:
Maximum speed: 5000r/min
1 rotor: 4 * 100ml
No. 2 rotor: 8 * 50ml
No. 3 rotor: 28 * 10ml
Motor: Brushless DC Motor
Timing range: 0-99min


Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
1.Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
2.Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
3.Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees - 60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
4.Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
5. To ensure safety, be sure to use ground wire
6.In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
7.Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish。Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
8. Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
9. Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
 

在線留言

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

掃碼加微信,了解最新動態(tài)

掃碼加微信
021-65682142

Copyright © 2025 上海碩光電子科技有限公司版權(quán)所有

技術(shù)支持:化工儀器網(wǎng)    sitemap.xml

滬公網(wǎng)安備 31011002005640號

亚洲二区无码AV在线精品| 久久国产精品-久久精品| 日本不卡码一区二区三区| 少妇伦子伦精品无码styles| 亚洲熟伦熟女新五十路熟| 日韩紧缚捆绑一区二区三区| 婷婷久久精品国产一区二区| 亚洲成a人片77777kkkk| 人妻丰满熟妇av无码区免| 粉嫩玉足夹茎视频在线看| 四虎成人精品国产永久免费无码| 站不卡在线观看| 香蕉视频成人网在线观看 | 欧美午夜理伦三级理论三级| 在线午夜福利网| 91色区在线免费观看国产| 人妻少妇久久精品一区二区| 夜夜爽久久精品国产三级| 天天婷婷三级片| 亚洲图套超市综合海外av| 午夜在线视频国产极品片| 在线观看免费av小黄片| 中文字幕免费视频精品一| 国产精品国产三级国产专播| 91人人妻人人澡人人精品| 亚洲国产不卡一区二区三区| 国产精品一区二区18禁| 免费无码国产一级AV片| 俺来也俺去?久久综合网| 欧美日韩一区二区免费高清| 国产成人精品视频免费看| 久久久久亚洲av成人无码网站| 精品国精品国产自在久国产 | 亚洲欧美日韩一区制服丝袜| 免费在线看污的视频网站| 成人短视频在线观看视频| 被按摩师玩弄到潮喷在线播放| 亚洲av无码国产在丝袜线观看| 九九热这里只有精品17| 国产精品巨作av色呦呦| 国产精品久久久久久人妻|